Characteristic:
1.Built-in zero export function(Optional)
2.Precise MPPT algorithm, over 97.8% Max. efficiency
3.Built-in WiFi / GPRS with real time PV Monitoring
4.High frequency switching technology- Smaller Smarter
5.Natural Ventilation, Mute Operation
Technical Data GW4000-DT GW5000-DT GW5000L-DT GW6000-DT GW6000L-DT GW8000-DT GW10KN-DT GW10KL-DT
PV String Input Data
Max. DC Input Power (W) 5200 6500 6500 7800 7800 9600 12000 12000
Max. DC Input Voltage (V) 1000 1000 600 1000 600 1000 1000 600
MPPT Range (V) 200~800 200~800 200~550 200~800 200~550 200~850 200~850 200~550
Start-up Voltage (V) 180 180 180 180 180 180 180 180
Nominal DC Input Voltage (V) 620 620 480 620 480 620 620 480
Max. Input Current (A) 11/11 11/11 11/11 11/11 11/11 11/11 11/11 22/11
Max. Short Current (A) 13.8/13.8 13.8/13.8 13.8/13.8 13.8/13.8 13.8/13.8 13.8/13.8 13.8/13.8 27.6/13.8
No. of MPP Trackers 2 2 2 2 2 2 2 2
No. of Input Strings per Tracker 1/1 1/1 1/1 1/1 1/1 1/1 1/1 2/1
AC Output Data
Nominal Output Power (W) 4000*1 5000*1 5000 6000*1 6000 8000*1 10000*1 10000
Max. Output Apparent Power (VA) 4000 5000 5000 6000 6000 8000 10000 10000
Nominal Output Voltage (V) 400, 3L/N/PE 400, 3L/N/PE 400, 3L/N/PE 400, 3L/N/PE 400, 3L/N/PE 400, 3L/N/PE 400, 3L/N/PE 400, 3L/N/PE
Nominal Output Frequency (Hz) 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60
Max. Output Current (A) 8.5 8.5 8.5 10 10 12.1 15.2 15.2
Output Power Factor ~1 (Adjustable from 0.8 leading to 0.8 lagging)
Output THDi (@Nominal Output) <2% <2% <2% <2% <2% <2% <2% <2%
Efficiency
Max. Efficiency 98.0% 98.0% 98.0% 98.0% 98.0% 98.3% 98.3% 98.3%
European Efficiency >97.5% >97.5% >97.5% >97.5% >97.5% >98.0% >98.0% >98.0%
Protection
PV String current Monitoring Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated
Anti-islanding Protection Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated
Input Reverse Polarity Protection Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated
Insulation Resistor Detection Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated
Residual Current Monitoring Unit Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated
Output Over Current Protection Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated
Output Short Protection Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated
Output Over Voltage Protection Integrated Integrated Integrated Integrated Integrated Integrated Integrated Integrated
DC SPD Protectioin Integrated(Type III)
AC SPD Protection Integrated(Type III)
General Data
OperatingTemperature Range (°C) -25~60 -25~60 -25~60 -25~60 -25~60 -25~60 -25~60 -25~60
Relative Humidity 0~100% 0~100% 0~100% 0~100% 0~100% 0~100% 0~100% 0~100%
Operating Altitude (m) ≤4000 ≤4000 ≤4000 ≤4000 ≤4000 ≤4000 ≤4000 ≤4000
Cooling Natural Convection Natural Cooling
Noise (dB) <30 <30 <30 <30 <30 <30 <30 <30
User Interface LCD & LED LCD & LED LCD & LED LCD & LED LCD & LED LCD & LED LCD & LED LCD & LED
Communication RS485 or WiFi RS485 or WiFi RS485 or WiFi RS485 or WiFi RS485 or WiFi RS485 or WiFi RS485 or WiFi RS485 or WiFi
Weight (kg) 24 24 24 24 24 24 24 26
Size (Width*Height*Depth mm) 516*415*192 516*415*192 516*415*192 516*415*192 516*415*192 516*415*192 516*415*192 516*455*192
Protection Degree IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65
Night Self Consumption (W) <1 <1 <1 <1 <1 <1 <1 <1
Topology Transformerless Transformerless Transformerless Transformerless Transformerless Transformerless Transformerless Transformerless
Certifications & Standards
Grid Regulation VDE0126-1-1, VDE-AR-N 4105, EN50438,
CEI 0-21 AS4777.2, VDE0126-1-1, VDE-AR-N 4105, EN50438,
CEI 0-21 AS4777.2
VDE0126-1-1, VDE-AR-N 4105, EN50438,
CEI 0-21 VDE0126-1-1, VDE-AR-N 4105, EN50438,
CEI 0-21 AS4777.2, VDE0126-1-1, VDE-AR-N 4105, EN50438,
CEI 0-21 VDE0126-1-1, AS4777.2,
G83, IEC61727, IEC62116, EN50438(SW), EN50438(IR) VDE0126-1-
1, AS4777.2,
G83, IEC61727,
IEC62116,
EN50438(SW),
EN50438(IR),
CEI 0-21 VDE0126-1-1, AS4777.2,
G83, IEC61727, IEC62116, EN50438(SW), EN50438(IR), CEI 0-21
Safety Regulation IEC62109-1&-2
EMC EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4, EN61000-4-16, EN61000-4-18, EN61000-4-29
CEI 0-21
CEI 0-21
VDE0126-1-1, VDE-AR-N 4105, EN50438,
CEI 0-21
CEI 0-21
CEI 0-21
G83, IEC61727, IEC62116, EN50438(SW), EN50438(IR)
1, AS4777.2,
G83, IEC61727,
IEC62116,
EN50438(SW),
EN50438(IR),
CEI 0-21
G83, IEC61727, IEC62116, EN50438(SW), EN50438(IR), CEI 0-21
Đánh giá